DescriptionWith the hand-held HI 93114, three important parameters in water
quality analysis are at your fingertips. Free and total chlorine
measurements and US EPA compliant turbidity measurements are performed
quickly and reliably with this lab-grade microprocessor-based field
instrument. HI 93114 is particularly useful for potable water
measurements and municipalities.
The rugged HI 93114 will log
data for up to 25 measurements along with time and date information for
retrieval at a later date. This instrument also offers Good Laboratory
Practice (GLP) features which allow the user to verify the calibration
status of the meter.
With HI 93114 measurements can be performed
using either concentration or relative absorbance of the sample
depending on the requirements of the application.
HI 93114 can be
calibrated using the factory preprogrammed calibration points or can be
custom calibrated when in colorimetric mode.
This rugged
instrument has been engineered to offer all the sophistication and
reliability of bench top laboratory instrumentation in the size of a
hand-held meter.
SPECIFICATIONRange |
Turbidity |
0.00 to 9.99 FTU; 10.0 to 50.0 FTU |
Range |
Free Chlorine |
0.00 to 2.50 mg/L |
Range |
Total Chlorine |
0.00 to 3.50 mg/L |
Resolution |
Turbidity |
0.01 FTU (0.00 to 9.99 FTU); 0.1 FTU (10.0 to 50.0 FTU) |
Resolution |
Chlorine |
0.01 mg/L |
Accuracy |
Turbidity |
±0.5 FTU or ±5% of reading (whichever is greater) |
Accuracy |
Chlorine |
±0.03 mg/L or ±3% of reading (whichever is greater) |
Calibration |
|
2 points, selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended) |
Light Source |
|
Green LED |
Light Life |
|
Life of the instrument |
Light Detection |
|
2 Silicon Photocells |
Battery Type / Life |
|
4 x 1.5V AA / approx. 60 hours of continuous use or 1000 measurements; automatic shut-off after 10, 20, 30, 40, 50 or 60 minutes (User-Selectable) |
Environment |
|
0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions |
|
220 x 82 x 66 mm (8.7 x 3.2 x 2.6") |
Weight |
|
510 g (1.1 lb.) |
With
the hand-held HI 93114, three important parameters in water quality
analysis are at your fingertips. Free and total chlorine measurements
and US EPA compliant turbidity measurements are performed quickly and
reliably with this lab-grade microprocessor-based field instrument. HI
93114 is particularly useful for potable water measurements and
municipalities.
The rugged HI 93114 will log data for up to 25
measurements along with time and date information for retrieval at a
later date. This instrument also offers Good Laboratory Practice (GLP)
features which allow the user to verify the calibration status of the
meter.
With HI 93114 measurements can be performed using either
concentration or relative absorbance of the sample depending on the
requirements of the application.
HI 93114 can be calibrated using
the factory preprogrammed calibration points or can be custom
calibrated when in colorimetric mode.
This rugged instrument has
been engineered to offer all the sophistication and reliability of
bench top laboratory instrumentation in the size of a hand-held meter.
Range |
Turbidity |
0.00 to 9.99 FTU; 10.0 to 50.0 FTU |
Range |
Free Chlorine |
0.00 to 2.50 mg/L |
Range |
Total Chlorine |
0.00 to 3.50 mg/L |
Resolution |
Turbidity |
0.01 FTU (0.00 to 9.99 FTU); 0.1 FTU (10.0 to 50.0 FTU) |
Resolution |
Chlorine |
0.01 mg/L |
Accuracy |
Turbidity |
±0.5 FTU or ±5% of reading (whichever is greater) |
Accuracy |
Chlorine |
±0.03 mg/L or ±3% of reading (whichever is greater) |
Calibration |
|
2 points, selectable between 0.00 - 50.0 FTU (0.00 and 20.0 FTU recommended) |
Light Source |
|
Green LED |
Light Life |
|
Life of the instrument |
Light Detection |
|
2 Silicon Photocells |
Battery Type / Life |
|
4 x 1.5V AA / approx. 60 hours of continuous use or 1000 measurements; automatic shut-off after 10, 20, 30, 40, 50 or 60 minutes (User-Selectable) |
Environment |
|
0 to 50°C (32 to 122°F); RH max 95% non-condensing |
Dimensions |
|
220 x 82 x 66 mm (8.7 x 3.2 x 2.6") |
Weight |
|
510 g (1.1 lb.) |
Solutions |
HI 93102-0 |
AMCO-AEPA-1 Calibration Solution at 0 NTU |
HI 93102-20 |
AMCO-AEPA-1 Calibration Solution at 20 NTU |
Accessories |
HI 731318 |
Tissue for Wiping Cuvets |
HI 731321 |
Glass Cuvet for HI 937xx & HI 832xx Series Meters |
HI 731327 |
Maintenance Kit for HI 93102 & HI 93114 |
Reagents & Standards |
HI 93701-01 |
Chlorine, free, DPD Method (100 Tests) |
HI 93701-03 |
Chlorine, free, DPD Method (300 Tests) |
HI 93711-01 |
Chlorine, Total, DPD Method (100 Tests) |
HI 93711-03 |
Chlorine, Total, DPD Method (300 Tests) |
HI 93114 is supplied with glass cuvet, batteries and instructions.