| Parameter |
Condition |
Limit |
|
Input
|
| Input
Voltage |
x |
100/120/220/230/240 Vac
Selectable |
| Input
Frequency |
x |
47-63
Hz |
|
Output
|
| Line
Regulation |
for
10% change |
0.05% |
| Load
Regulation |
for
50% change |
0.05% |
| Ripple |
x |
3.0
mV maximum Peak-to-Peak |
| DC
Output Adjustment Range |
x |
±5%
Minimum |
| Overvoltage
Protection |
x |
All
5-Volt outputs include build-in OVP as
standard (setting is
6.2 V ±0.4 V) OVP is optionally available on other
types
|
| Transient
Response Time |
at
50% Load Changes |
50
msec. |
| Overload
Protection |
|
Automatic
current limit foldback |
| Remote
Sensing |
Available
to compensate for output voltage drop on selected
models
|
0.5
Vdc
|
|
General
|
| Operating
Temperature
Range |
Derate
to 40% at +70°C
|
0
to +50°C |
|
Storage
Temperature Range
|
|
-25°C
to +85°C |
| Temperature Coefficient
(Typical) |
|
0.01%°C |
| Stability |
After
warm-up |
±
0.5% |
| EMI/RFI |
Linear
power supplies have inherently low conducted
and radiate noise levels
|
For
most system applications they will meet
requirements
of FCC Class B and VDE 0871 for Class B
|
| Cover
Option |
Derate
power by an additional 15%
|
| Cooling |
Forced
air. 20 CFM required for full rating Derate 30%
without cooling.
|
| *Specifications
are typical. Load Regulation on outputs without
Remote Sense, 0.1%
typical. |